460kW air cooled scroll chiller
Features
EKAC series air-cooled chiller (heat pump) units are highly reliable, secure and flexible.
This series of units are elaborately designed to be delicate and elegant. In addition, they can support fan coils and air handling units of various specifications and models.
Units of this series are marked for their high efficiency, low noise, user-friendliness, secure operation, easy installation and maintenance etc, and are widely used in factories, stations, hotels, villas, office buildings, top-grade residences etc. Besides, they can also be used in industrial chilling.
EKAC1600 series units feature 4-grade modulation which can be transformed to multi-grade modulations in modular combinations. For example, 16 EKAC1600 units can realize 16 modulation grades with effects very similar to that of stepless modulation. With operation grades controlled electronically, the unit exerts less shock to the power grid and saves more energy.
EKAC series units feature leading-edge technologies and name-brand accessories which are strictly tested for compatibility. Fully hermetic volute compressor and low-noise fans minimize the operation noise. With efficient volute compressors and precise throttling systems with electronic expansion valves, the units feature high EER and COP, especially at partial workload.
Units can be controlled individually or together by an electronic controller. The controller is strongly interference proof and can exert control from as far as 1000 meters away. Failures are indicated by error codes displayed on the controller to facilitate troubleshooting.
The units are designed to best facilitate installation. The cooling system is made hermetic in the factory. Customers do not need to connect any copper pipe or refill refrigerant. The water system has an inlet connector which is to be connected to the terminal equipment. Having installed the unit as instructed, customers just need to check that water and pump pipes are clean before pumping water and powering on the unit.
The controller defrosts the unit automatically according to the operation time of the unit and the temperature of the heat exchanger.
The cooling system is protected against extreme pressures: discharge pressure will not be too high, nor will inhaling pressure be too low; against extreme discharge temperature: discharge temperature will not be too high; against freezing during cooling operation: when the water temperature is too low, the plate heat exchanger will not freeze up or burst internally; and against low temperature: during cold winter time, the water pipe and plate heat exchanger will not freeze up or burst internally (This feature works only when the system is working in the heating mode with the main power supply turned on).
The unit shell is made of galvanized, phosphorized steel plate with pure polyester plating to withstand weathering. The unit is reasonably designed to save space. It can be mounted on walls, balconies or the roof, thus eliminating the need for a dedicated equipment room.
The unit is highly adaptive and can operate smoothly in hostile conditions such as extremely high or low temperatures.
To access and service any part of the unit, you just need to dismantle the side panel or the front panel. When the unit stops working abnormally, the controller prompts the reason to facilitate troubleshooting.
Specifications:
Model | EKAC1600C1M | EKAC1600CR1M | ||
Nominal cooling capacity | kW | 460 | 460 | |
Nominal heating capacity | kW | - | 470 | |
Total power of nominal cooling capacity | kW | 138 | 138 | |
Total power of nominal Heating capacity | kW | - | ||
Nominal cooling operation current | A | |||
Nominal heating operation current | A | - | ||
EER | COP | 3.33 | 3.33 | |
Power supply | 380V/3N~/50Hz | |||
Refrigerant Type | R410A | |||
Refrigerant Control | Electronic Expansion Valve | |||
Compressor | Type | Scroll | ||
Qty | Nr | 4 | 4 | |
Model | CH485 | CH485 | ||
Brand | DANFOSS | DANFOSS | ||
Lubricant | POE | |||
Water side heat exchanger | Type | Efficient shell tube heat exchanger | ||
Water Flow Cooling | m³/h | 79.1 | 79.1 | |
Water Flow Heating | m³/h | - | ||
Water resistance | kPa | |||
Pipe | Min.size of inlet/outlet water pipe connector | DN125 | ||
Recommended length of inlet/outlet water pipe | inch | depend on water pump | ||
Fan Condenser | Type | Axial Fan | ||
Qty | Nr | 8 | 8 | |
Unit | Length | mm | 4630 | 4630 |
Width | mm | 2265 | 2265 | |
Height | mm | 2425 | 2425 | |
Net Weight | Kg | 3340 | 3360 |
Note:
1. Working conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172m³/(h·kW); outdoor ambient temperature 35°C.
2. Working conditions for nominal heating capacity: outlet water temperature 45°C; water flow: 0.172 m³/(h·kW); outdoor dry / web bulb temperature 7°C / 6°C.
3. Water resistance excludes water pressure drop of the unit and the attached Y-shaped filter;
4. A maximum of 16 units can be connected to form a modular combination.
5. Specifications are subject to change due to design variations without further notice.