Add to Cart
Humidifying (AHU) air handling units with backward fan high ESP
EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.
• The surface of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.
• Internal panels are made of steel plates galvanized with aluminum and zinc, with an assured service life of more than 15 years. All panels feature end-to-end joints and smooth surfaces, without any bur or corroded point.
• The internal panels feature reinforced design, which is strong enough to support the largest air handling unit.
• The unit panel has two thicknesses, namely 30mm and 50mm.Inside the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat- insulating material. The heat conductivity factor is less than 0.02W/m°C.
• Each functional section of the unit is equipped with a steel trough base, thus ensuring it is well supported, easy to transport and assemble. The overall robustness of the unit meets the standard of CEN2.
Humidifying section
The relative humidity of the air changes as areas and seasons change. Different operating conditions have different requirements on humidity. In dry areas and seasons, or in environment that requires high humidity, you may need to install a humidifier. Standard humidifiers for EKDM series units use dry steam. In addition, EK also provides high-pressure spray, wet film humidifying, electrode humidifying etc. If you have any special requirements on humidifying, please contact EK.
Humidifier Introduction
High-pressure spray humidifier—equal-enthalpy humidifying; water distribution pipes and nozzles made from stainless steel; high pressure spray; efficient, safe, reliable and energy saving.
Wet film humidifier— saturation efficiency; space-saving; reducing total length of the unit; no water handling; safe and reliable.
Dry steam humidifier—equal-temperature humidifying; high humidifying efficiency; made from stainless steel; graceful exterior; and corrosion proof.
Electrode humidifier—high humidifying efficiency; multiple control solutions to choose from.
Electric heating humidifier——efficient and accurate.
Humidifier Comparison
Type of humidifier | Working conditions | ||||||
Environment temp. (°C) | Humidity | Critical wind speed (m/s) | Water quality | Water/steam temp. (°C) | Water/steam pressure (MPa) | Length of humidifying section (mm) |
|
High-pressure spray humidifier | 1 ~ 40 | ≤ 85% | 0.5 ~ 3.5 | Tap water, purified water or water with similar quality | 4 ~ 55 | 0.1 ~ 0.5 | 960 |
Dry steam humidifier | -10 ~ 50 | / | 0.5 ~ 3.5 | Steam | 0<150 | 0.02 ~ 0.4 | 640 |
Wet film humidifier | 5 ~ 100 | < 90% | ≤ 4.0 | Tap water or water with similar quality | 5 ~ 40 | 0.15 ~ 0.75 | Can be installed together with cooling coil |
Electrode humidifier | 0 ~ 40 | < 85% | / | Clean tap water or softened water | 4 ~ 35 | 0.1 ~ 1.0 | 640 |
Electric heating humidifier | 0 ~ 40 | < 85% | / | Clean tap water, softened water or deionized water | 4 ~ 35 | 0.1 ~ 0.3 | 640 |
Dry Steam Humidifier
Humidifiers should be chosen according to the control solution, steam pressure, required humidifying capacity and the width of the unit.
Dry Steam Humidifying Capacity Table
model Nozzle Dia. |
GZQ - 15 | GZQ -20 | GZQ -40 | GZQ -50 | |||||||
Steam pressure | φ2 | φ4 | φ6 | φ8 | φ9 | φ10 | φ10.5 | φ12 | φ14 | φ16 | φ18 |
0.02MPa | 1.5 | 4 | 9 | 22.5 | 27 | 34 | 40 | 55 | 75 | 145 | 187 |
0.1MPa | 2.3 | 9.4 | 21.3 | 49.5 | 62 | 75.5 | 78 | 102 | 141 | 194 | 246 |
0.2MPa | 3.6 | 14 | 35 | 68.5 | 106 | 131 | 142 | 160 | 216 | 311 | 397 |
0.3MPa | 4.5 | 18.3 | 40 | 97.5 | 152 | 187 | 205 | 217 | 296 | 448 | 569 |
0.4MPa | 6.1 | 24.5 | 58.5 | 124 | 196 | 227 | 250 | 275 | 375 | 590 | 760 |
Unit width | 4M | 5M | 6M | 7M | 8M | 9M | 10M | 11M | 12M | 13M | 14M |
Spout code | L3 | L3 | L4 | L4 | L5 | L5 | L6 | L6 | L7 | L7 | L8 |
Weight of Model 15 (kg) | 10 | 10 | 11 | 11 | 12 | 12 | 13 | 13 | 14 | 14 | 15 |
Weight of Model 20 (kg) | 12 | 12 | 13 | 13 | 14 | 14 | 15 | 15 | 16 | 16 | 17 |
Weight of Model 40 (kg) | 13 | 13 | 14 | 14 | 15 | 15 | 16 | 16 | 17 | 17 | 19 |
Weight of Model 50 (kg) | 14 | 14 | 15 | 15 | 16.5 | 16.5 | 18 | 18 | 19 | 19 | 21 |
Unit width | 15M | 16M | 17M | 18M | 19M | 20M | 21M | 22M | 23M ~ 26M |
Spout code | L8 | L9 | L9 | L10 | L10 | L11 | L11 | L12 | L13 |
Weight of Model 15 (kg) | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 |
Weight of Model 20 (kg) | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 |
Weight of Model 40 (kg) | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 |
Weight of Model 50 (kg) | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 |
Wet film humidifier
Wet film humidifier humidifies the air through natural water evaporation. Its paper-like medium is made of macromolecule inorganic material which is highly hydrophilic. When dry air passes through the medium, water in the medium takes up heat in the air and evaporates to humidify the air. Wet film humidifier can use domestic water or tap water, and has the following advantages:
■ Clean humidification—no “white powder” produced during temperature drop
■ Humidifying distance—the thickness of the wet film itself
■ High saturation efficiency—up to 80%
■ Safe and reliable—the film material is mildew and bacteria proof, with a service life up to 8 ~ 10 years
■ Excellent cooling performance—cooling through filling-catalyzed direct evaporation; more efficient cooling with less space Wet-film Humidifying Capacity for Typical Units
Model EKDM | Rated air flow m3/h |
Fresh air conditions (kg/h) | Return air conditions (kg/h) | ||||||
35% efficiency |
60% efficiency |
75% efficiency |
85% efficiency |
35% efficiency |
60% efficiency |
75% efficiency |
85% efficiency |
||
306 | 2000 | 4 | 9 | 11 | 12 | 4 | 7 | 9 | 10 |
406 | 3000 | 7 | 13 | 16 | 18 | 5 | 10 | 13 | 15 |
407 | 4000 | 8 | 15 | 20 | 22 | 7 | 13 | 16 | 18 |
408 | 5000 | 9 | 18 | 23 | 26 | 8 | 15 | 19 | 22 |
508 | 6000 | 13 | 24 | 31 | 35 | 10 | 20 | 25 | 29 |
607 | 7000 | 14 | 26 | 33 | 37 | 11 | 21 | 27 | 31 |
608 | 8000 | 16 | 30 | 39 | 44 | 13 | 25 | 32 | 36 |
511 | 9000 | 19 | 35 | 45 | 52 | 15 | 29 | 37 | 42 |
610 | 10000 | 21 | 39 | 50 | 57 | 17 | 32 | 41 | 47 |
611 | 12000 | 23 | 44 | 56 | 64 | 19 | 36 | 46 | 52 |
712 | 15000 | 30 | 58 | 74 | 84 | 25 | 48 | 60 | 69 |
812 | 18000 | 35 | 67 | 86 | 98 | 29 | 55 | 70 | 80 |
813 | 20000 | 39 | 74 | 94 | 107 | 32 | 60 | 77 | 88 |
915 | 25000 | 52 | 99 | 126 | 144 | 42 | 81 | 103 | 118 |
1015 | 30000 | 60 | 114 | 145 | 166 | 49 | 93 | 119 | 136 |
1313 | 35000 | 67 | 128 | 163 | 187 | 55 | 105 | 134 | 153 |
1315 | 40000 | 79 | 150 | 191 | 219 | 64 | 123 | 157 | 179 |
1515 | 45000 | 91 | 175 | 222 | 254 | 75 | 143 | 182 | 208 |
1417 | 50000 | 97 | 185 | 237 | 271 | 80 | 153 | 194 | 222 |
1520 | 60000 | 122 | 233 | 297 | 339 | 100 | 191 | 243 | 278 |
1720 | 70000 | 139 | 266 | 338 | 386 | 114 | 218 | 277 | 316 |
1722 | 80000 | 154 | 295 | 375 | 429 | 126 | 241 | 307 | 351 |
1626 | 90000 | 173 | 332 | 422 | 482 | 142 | 272 | 346 | 395 |
1826 | 100000 | 196 | 375 | 477 | 545 | 160 | 307 | 391 | 446 |
Note: standard fresh air conditions: temperature of 28°C and relative humidity of 15%; mixed air conditions: containing 30% of fresh air.
Specifciations
Model EKDM |
Rated air flow m3/h | Windward area of coil (m2) | Air flow (m3/h) | Diameter of fan impeller mm | Fan performance | ||||
2.25 | 2.50 | 2.75 | 3.00 | Max. total pressure of fan Pa | Max. motor power kW | ||||
m/s | m/s | m/s | m/s | ||||||
306 | 2000 | 0.23 | 1863 | 2070 | 2277 | 2484 | 160 | 1300 | 2.2 |
406 | 3000 | 0.34 | 2754 | 3060 | 3366 | 3672 | 200 | 1300 | 3 |
407 | 4000 | 0.41 | 3321 | 3690 | 4059 | 4428 | 225 | 1500 | 3 |
408 | 5000 | 0.48 | 3888 | 4320 | 4752 | 5184 | 250 | 1800 | 5.5 |
508 | 6000 | 0.65 | 5265 | 5850 | 6435 | 7020 | 280 | 1800 | 7.5 |
607 | 7000 | 0.69 | 5589 | 6210 | 6831 | 7452 | 280 | 1800 | 7.5 |
608 | 8000 | 0.81 | 6561 | 7290 | 8019 | 8748 | 315 | 1800 | 7.5 |
511 | 9000 | 0.94 | 7614 | 8460 | 9306 | 10152 | 315 | 1800 | 11 |
610 | 10000 | 1.05 | 8505 | 9450 | 10395 | 11340 | 355 | 2000 | 11 |
611 | 12000 | 1.17 | 9477 | 10530 | 11583 | 12636 | 400 | 2000 | 15 |
712 | 15000 | 1.55 | 12555 | 13950 | 15345 | 16740 | 450 | 2000 | 15 |
812 | 18000 | 1.81 | 14661 | 16290 | 17919 | 19548 | 500 | 2000 | 18.5 |
813 | 20000 | 1.98 | 16038 | 17820 | 19602 | 21384 | 500 | 2000 | 18.5 |
915 | 25000 | 2.66 | 21546 | 23940 | 26334 | 28728 | 560 | 2000 | 22 |
1015 | 30000 | 2.99 | 24219 | 26910 | 29601 | 32292 | 630 | 2000 | 30 |
1313 | 35000 | 3.40 | 27540 | 30600 | 33660 | 36720 | 630 | 2000 | 30 |
1315 | 40000 | 3.99 | 32319 | 35910 | 39501 | 43092 | 710 | 2000 | 30 |
1515 | 45000 | 4.65 | 37665 | 41850 | 46035 | 50220 | 800 | 2000 | 37 |
1417 | 50000 | 4.95 | 40095 | 44550 | 49005 | 53460 | 800 | 2000 | 45 |
1520 | 60000 | 6.36 | 51516 | 57240 | 62964 | 68688 | 900 | 2000 | 45 |
1720 | 70000 | 7.27 | 58887 | 65430 | 71973 | 78516 | 900 | 2000 | 55 |
1722 | 80000 | 8.05 | 65205 | 72450 | 79695 | 86940 | 1000 | 2000 | 75 |
1626 | 90000 | 9.01 | 72981 | 81090 | 89199 | 97308 | 1000 | 2000 | 75 |
1826 | 100000 | 10.21 | 82701 | 91890 | 101079 | 110268 | 1120 | 2000 | 110 |
1852 | 2000000 | 20.42 | 165402 | 183780 | 202158 | 220536 | 1120x2 | 2000 | 110x2 |
3652 | 4000000 | 40.84 | 330804 | 367560 | 404316 | 441072 | 1120x4 | 2000 | 110x4 |
Note:
■ This table only lists some typical models among many models for quick model selection.
■ Total fan pressures listed above are tested on standard fans with rated air flow.
■ External residual pressure = Total fan pressure - Internal resistance. For internal resistance of EKDM units.