Add to Cart
EK keeps looking for valuable distributors and partners around international markets…
Vertical type cabinet F7 filter 4/6 rows coil air handling units with 30/50 mm PU insulation
EUROKLIMAT possesses the most advanced technologies and manufacturing facilities/processes in the air conditioning sector and has been forging ahead at the forefront of air conditioning products and technologies for more than 40 years by enterprising innovation.
Launched by EK to meet market demand, EKDW series air handling units feature joggle structures and foamed polyurethane plates for effective heat preservation and service life enhancement. Units of this series have 40 models and 560 standard specifications available for your choice, and can be widely used in central air conditioning systems of hotels, shopping malls, hospitals, office buildings etc.
Functional section
Mixing
Primary efficiency filter
Cooling coil
Heating coil
Wet film humidifier
Electric heater
Bag-type filter with medium efficiency
Fan
Specifications
Model | EKDW 040V |
EKDW 050V |
EKDW 060V |
EKDW 070V |
EKDW 080V |
EKDW 090V |
EKDW 100V |
EKDW 120V |
EKDW 135V |
EKDW 150V |
||
Nominal air flow (m3/h) | 4000 | 5000 | 6000 | 7000 | 8000 | 9000 | 10000 | 12000 | 13500 | 15000 | ||
External residual pressure (Pa) | I | 80 | 80 | 80 | 80 | 80 | 80 | 80 | ~ | ~ | ~ | |
II | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | ||
III | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | ||
IV | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | ||
Nominal cooling capacity (kW) | 4 rows of coils (return air) | 23 | 30 | 37 | 44 | 50 | 56.3 | 63 | 74 | 84 | 95 | |
4 rows of coils (fresh air) | 55 | 70 | 83 | 94 | 111 | 121 | 137 | 167 | 190 | 202 | ||
6 rows of coils (return air) | 32 | 40 | 47 | 53 | 62 | 69 | 78 | 96 | 112 | 120 | ||
6 rows of coils (fresh air) | 70 | 86 | 103 | 122 | 137 | 156 | 172 | 206 | 230 | 264 | ||
Nominal heating capacity (kW) | 4 rows of coils (return air) | 40 | 50 | 60 | 71 | 82 | 91 | 102 | 122 | 139 | 155 | |
4 rows of coils (fresh air) | 65 | 82 | 98 | 115 | 129 | 148 | 164 | 197 | 222 | 246 | ||
6 rows of coils (return air) | 48 | 60 | 72 | 84 | 97 | 108 | 121 | 142 | 161 | 178 | ||
6 rows of coils (fresh air) | 77 | 94 | 113 | 132 | 152 | 169 | 191 | 224 | 257 | 280 | ||
Nominal cooling water flow (L/S) | 4 rows of coils (return air) | 1.10 | 1.43 | 1.76 | 2.10 | 2.80 | 2.68 | 3.00 | 3.52 | 4.00 | 4.52 | |
4 rows of coils (fresh air) | 2.62 | 3.33 | 3.95 | 4.48 | 5.29 | 5.76 | 6.52 | 7.95 | 9.05 | 9.62 | ||
6 rows of coils (return air) | 1.52 | 1.90 | 2.24 | 2.52 | 2.95 | 3.29 | 3.71 | 4.57 | 5.33 | 5.71 | ||
6 rows of coils (fresh air) | 3.33 | 4.10 | 4.90 | 5.81 | 6.52 | 7.43 | 8.19 | 9.81 | 10.95 | 12.57 | ||
Nominal heating water flow (L/S) | 4 rows of coils (return air) | 0.96 | 1.21 | 1.45 | 1.71 | 1.98 | 2.19 | 2.46 | 2.94 | 3.34 | 3.74 | |
4 rows of coils (fresh air) | 1.57 | 1.98 | 2.36 | 2.77 | 3.11 | 3.56 | 3.96 | 4.75 | 5.34 | 5.93 | ||
6 rows of coils (return air) | 1.16 | 1.45 | 1.74 | 2.02 | 2.34 | 2.60 | 2.92 | 3.43 | 3.87 | 4.29 | ||
6 rows of coils (fresh air) | 1.86 | 2.27 | 2.73 | 3.17 | 3.67 | 4.06 | 4.61 | 5.40 | 6.18 | 6.75 | ||
Coil | Type | Copper tube with a new type of wavy aluminum fins | ||||||||||
Piece/inch | 13 | |||||||||||
Working pressure (MPa) | 1.6 | |||||||||||
Size of inlet/outlet water pipe connector |
R 1-1/2 | R 1-1/2 | R 1-1/2 | R 2 | R 2 | R 2 | R 2 | R 2 | R 2 | R 2-1/2 | ||
Size of condensate water pipe connector |
R1-1/4 | |||||||||||
Fan | Type/material | High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates | ||||||||||
Transmission | V-belt transmission | |||||||||||
Fanning direction | Top | |||||||||||
Motor | Power supply | 380V/3~/50Hz | ||||||||||
Type | 3-phase asynchronous motor; insulation grade of F and protection grade of IP54 | |||||||||||
Motor power (kW) | I |
0.75 (0.75) |
0.75 (1.1) |
1.1 (1.1) |
1.1 (1.1) |
1.1 (1.5) |
1.5 (1.5) |
1.5 (2.2) |
~ | ~ | ~ | |
II |
0.75 (1.1) |
1.1 (1.1) |
1.1 (1.5) |
1.1 (1.5) |
1.5 (1.5) |
1.5 (2.2) |
2.2 (2.2) |
2.2 (2.2) |
2.2 (3.0) |
3.0 (3.0) |
||
III |
1.1 (1.1) |
1.1 (1.1) |
1.5 (1.5) |
1.5 (1.5) |
1.5 (2.2) |
2.2 (2.2) |
2.2 (2.2) |
2.2 (3.0) |
3.0 (3.0) |
3.0 (4.0) |
||
IV |
1.1 (1.5) |
1.1 (1.5) |
1.5 (2.2) |
1.5 (2.2) |
2.2 (2.2) |
2.2 (3.0) |
2.2 (3.0) |
3.0 (3.0) |
3.0 (4.0) |
4.0 (4.0) |
||
Filter | Type | Thickness (mm) | ||||||||||
Thickness (mm) | 8/21 | |||||||||||
Cabinet | Type | 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat preservation |
||||||||||
Unit Dimensions |
Length (mm) | 920 | 1030 | 1200 | 1230 | 1280 | 1290 | 1330 | 1440 | 1580 | 1870 | |
Width (mm) | 650 | 650 | 650 | 810 | 810 | 810 | 900 | 900 | 900 | 810 | ||
Height (mm) | 1270 | 1335 | 1385 | 1490 | 1550 | 1610 | 1800 | 1860 | 1860 | 1680 | ||
Unit weight | 4 rows of coils (kg) | 172 | 203 | 236 | 274 | 306 | 323 | 386 | 423 | 435 | 482 | |
6 rows of coils (kg) | 179 | 211 | 246 | 286 | 321 | 339 | 404 | 444 | 458 | 507 |
Model | EKDW 180V |
EKDW 200V |
EKDW 220V |
EKDW 250V |
EKDW 270V |
EKDW 300V |
EKDW 350V |
EKDW 400V |
EKDW 450V |
||
Nominal air flow (m3/h) | 18000 | 20000 | 22000 | 25000 | 27000 | 30000 | 35000 | 40000 | 45000 | ||
External residual pressure (Pa) | I | ~ | ~ | ~ | ~ | ~ | 220 | 220 | 220 | 220 | |
II | 150 | 150 | 150 | 150 | 150 | 300 | 300 | 300 | 300 | ||
III | 220 | 220 | 220 | 220 | 220 | 400 | 400 | 400 | 400 | ||
IV | 300 | 300 | 300 | 300 | 300 | 500 | 500 | 500 | 500 | ||
V | ~ | ~ | ~ | ~ | ~ | ~ | 600 | 600 | 600 | ||
Nominal cooling capacity (kW) | 4 rows of coils (return air) | 115 | 123 | 138 | 157 | 170 | 191 | 220 | 256 | 286 | |
4 rows of coils (fresh air) | 246 | 272 | 302 | 342 | 369 | 418 | 481 | 558 | 620 | ||
6 rows of coils (return air) | 142 | 160 | 173 | 197 | 211 | 239 | 276 | 318 | 354 | ||
6 rows of coils (fresh air) | 317 | 350 | 379 | 428 | 454 | 526 | 596 | 686 | 754 | ||
Nominal heating capacity (kW) | 4 rows of coils (return air) | 187 | 202 | 230 | 255 | 275 | 310 | 358 | 408 | 460 | |
4 rows of coils (fresh air) | 293 | 326 | 362 | 406 | 439 | 502 | 574 | 656 | 730 | ||
6 rows of coils (return air) | 215 | 238 | 266 | 300 | 325 | 366 | 424 | 484 | 542 | ||
6 rows of coils (fresh air) | 339 | 377 | 418 | 474 | 507 | 574 | 666 | 766 | 854 | ||
Nominal cooling water flow (L/S) | 4 rows of coils (return air) | 5.48 | 5.86 | 6.57 | 7.48 | 8.10 | 9.10 | 10.48 | 12.19 | 13.62 | |
4 rows of coils (fresh air) | 11.71 | 12.95 | 14.38 | 16.29 | 17.57 | 19.90 | 22.90 | 26.57 | 29.52 | ||
6 rows of coils (return air) | 6.76 | 7.62 | 8.24 | 9.38 | 10.05 | 11.38 | 13.14 | 15.14 | 16.86 | ||
6 rows of coils (fresh air) | 15.10 | 16.67 | 18.05 | 20.38 | 21.62 | 25.05 | 28.38 | 32.67 | 35.90 | ||
Nominal heating water flow (L/S) | 4 rows of coils (return air) | 4.51 | 4.87 | 5.55 | 6.15 | 6.63 | 7.48 | 8.64 | 9.84 | 11.10 | |
4 rows of coils (fresh air) | 7.07 | 7.86 | 8.73 | 9.79 | 10.59 | 12.11 | 13.85 | 15.82 | 17.61 | ||
6 rows of coils (return air) | 5.19 | 5.74 | 6.42 | 7.24 | 7.84 | 8.83 | 10.23 | 11.68 | 13.07 | ||
6 rows of coils (fresh air) | 8.18 | 9.09 | 10.08 | 11.43 | 12.23 | 13.85 | 16.07 | 18.48 | 20.60 | ||
Coil | Type | Copper tube with a new type of wavy aluminum fins | |||||||||
Piece/inch | 13 | ||||||||||
Working pressure (MPa) | 1.6 | ||||||||||
Size of inlet/outlet water pipe connector |
R 2-1/2 | R 2-1/2 | R 3 | R 3 | R3 | R3 | R3 | R3 | R3 | ||
Size of condensate water pipe connector |
R1-1/4 | ||||||||||
Fan | Type/material | High-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates | |||||||||
Transmission | V-belt transmission | ||||||||||
Fanning direction | Top | ||||||||||
Motor | Power supply | 380V/3~/50Hz | |||||||||
Type | 3-phase asynchronous motor; insulation grade of F and protection grade of IP54 | ||||||||||
Motor power (kW) | I | ~ | ~ | ~ | ~ | ~ | 7.5(7.5) | 7.5(11) | 11(11) | 11(11) | |
II | 4.0(4.0) | 4.0(4.0) | 4.0(5.5) | 4.0(5.5) | 5.5(5.5) | 7.5(7.5) | 11(11) | 11(11) | 11(15) | ||
III | 4.0(4.0) | 4.0(5.5) | 5.5(5.5) | 5.5(5.5) | 5.5(7.5) | 11(11) | 11(11) | 15(15) | 15(15) | ||
IV | 4.0(5.5) | 5.5(5.5) | 5.5(7.5) | 5.5(7.5) | 7.5(7.5) | 11(11) | 11(15) | 15(15) | 15(15) | ||
V | ~ | ~ | ~ | ~ | ~ | ~ | 15(15) | 15(15) | 15(18.5) | ||
Filter | Type | Thickness (mm) | |||||||||
Thickness (mm) | 8/21 | ||||||||||
Cabinet | Type | 30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat preservation |
|||||||||
Unit Dimensions |
Length (mm) | 2060 | 2250 | 2310 | 2480 | 2630 | 2770 | 2770 | 2930 | 3090 | |
Width (mm) | 810 | 900 | 900 | 900 | 900 | 1010 | 1010 | 1010 | 1170 | ||
Height (mm) | 1740 | 1860 | 1920 | 1990 | 1990 | 2270 | 2590 | 2750 | 2810 | ||
Unit weight | 4 rows of coils (kg) | 537 | 649 | 674 | 779 | 807 | 968 | 1040 | 1196 | 1384 | |
6 rows of coils (kg) | 567 | 682 | 710 | 820 | 851 | 1021 | 1099 | 1267 | 1461 |
Note:
■ The above parameters are for standard units. However, EK can customize these parameters to meet special requirements from customers.
■ Working conditions for cooling under nominal return air flow: dry bulb 27°C, wet bulb 19.5°C; working conditions for cooling under nominal fresh air flow: dry bulb 34°C, wet bulb 28°C; water temperature under nominal cooling capacity: inlet water 7°C, outlet water 12°C.
■ Working conditions for heating under nominal return air flow: dry bulb 21°C; Working conditions for heating under nominal fresh air flow: dry bulb 0°C; water temperature under nominal heating capacity: inlet water 60°C, outlet water 50°C.
■ Weight listed in the above table are net weight of units. Operation weight may post an increase of 20%.
■ Parameters inside ( ) are the power of units with 6 rows of coils.
■ The coil loops for units with full return air ("R") and units with full fresh air ("F") may be different. Please specify the inlet air conditions while placing orders. EK can provide computer-aided model selection to
meet special requirements. For detailed
Aluminum Filter
■ Used to filter large particles, such as smog;
■ The aluminum frame helps to reduce maintenance cost;
■ The precision aluminum screen is easy to install and clean.
Electronic Purification Apparatus
■ A high-voltage static dedusting technology is applied to effectively filter all sorts of dust, bacteria,
virus and harmful gas;
■ Multi-layered filtering provides multi-layered protection;
■ A modular design can meet various air flow requirements.
Photocatalyst Ultraviolet Sterilamp
■ The sterilamp can effectively dampening the growth of bacteria and mildew and thereby
eliminating odor caused by such growth;
■ The photocatalyst itself is stable and unconsumed, and therefore can be effective for a long
time;
■ The sterilamp can effectively degrade contaminants such as formaldehyde, toluene and
ammonia into harmless and nontoxic materials, and does not cause secondary contamination.
Wet film humidifier
Tap water purified by the solenoid valve flows directly into the water distributor at the top of the
humidifier through water pipes and then flows down to wet the wet film under the pull of gravity.
Residual water collected by the water collector flows into the sewage through the drainpipe (water
will not be recycled). Hot air passing through the wet film is dampened and cooled (equal enthalpy
wetting). During this course, some water in the wet film is evaporated without consuming additional
energy. The work principle of wet film humidifier with direct water flow is shown in the figure on the
right side.