Brand Name :EuroKlimat
Model Number :EKDM
Certification :ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Place of Origin :China
MOQ :1 pcs
Price :Negotiation
Payment Terms :L/C, T/T
Supply Ability :15,00pcs per month
Delivery Time :20 working days after received your payment
Packaging Details :Plywood
Product Name :Air Handling Units
Installation :Ceiling hang/floor installation
Cooling Capacity(kW) :12-5200-
Heating Capacity(kW) :7-1296
Air Flow(m3/s) :1,000-400,000
Max. total pressure of fan (Pa) :2,000
Plate heat recovery :Optional
Humidifier :Optional
Thermal wheel heat recovery :Optional
Air damper :Optional
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

High air flow heat recovery air handling units

Specifications:

Quick Model Selection for Typical Units

Model
EKDM

Rated

air flow

m3/h

Windward

area of

coil (m2)

Air flow (m3/h)

Diameter of

fan impeller mm

Fan performance
2.25 2.50 2.75 3.00

Max. total

pressure

of fan Pa

Max. motor

power kW

m/s m/s m/s m/s
306 2000 0.23 1863 2070 2277 2484 160 1300 2.2
406 3000 0.34 2754 3060 3366 3672 200 1300 3
407 4000 0.41 3321 3690 4059 4428 225 1500 3
408 5000 0.48 3888 4320 4752 5184 250 1800 5.5
508 6000 0.65 5265 5850 6435 7020 280 1800 7.5
607 7000 0.69 5589 6210 6831 7452 280 1800 7.5
608 8000 0.81 6561 7290 8019 8748 315 1800 7.5
511 9000 0.94 7614 8460 9306 10152 315 1800 11
610 10000 1.05 8505 9450 10395 11340 355 2000 11
611 12000 1.17 9477 10530 11583 12636 400 2000 15
712 15000 1.55 12555 13950 15345 16740 450 2000 15
812 18000 1.81 14661 16290 17919 19548 500 2000 18.5
813 20000 1.98 16038 17820 19602 21384 500 2000 18.5
915 25000 2.66 21546 23940 26334 28728 560 2000 22
1015 30000 2.99 24219 26910 29601 32292 630 2000 30
1313 35000 3.40 27540 30600 33660 36720 630 2000 30
1315 40000 3.99 32319 35910 39501 43092 710 2000 30
1515 45000 4.65 37665 41850 46035 50220 800 2000 37
1417 50000 4.95 40095 44550 49005 53460 800 2000 45
1520 60000 6.36 51516 57240 62964 68688 900 2000 45
1720 70000 7.27 58887 65430 71973 78516 900 2000 55
1722 80000 8.05 65205 72450 79695 86940 1000 2000 75
1626 90000 9.01 72981 81090 89199 97308 1000 2000 75
1826 100000 10.21 82701 91890 101079 110268 1120 2000 110
1852 2000000 20.42 165402 183780 202158 220536 1120x2 2000 110x2
3652 4000000 40.84 330804 367560 404316 441072 1120x4 2000 110x4

Note:

■ This table only lists some typical models among many models for quick model selection.

■ Total fan pressures listed above are tested on standard fans with rated air flow.

■ External residual pressure = Total fan pressure - Internal resistance. For internal resistance of EKDM units, please refer to Page 23.

Typical Unit Performance Parameters - Cooling with Return Air

Unit model EKDM Rated air flow m3/h 1 row
Return air conditions Fresh air conditions
Total cooling capacity kW Water flow l/s Water resistance kPa Pipe diameter DN Total cooling capacity kW Water flow l/s Water resistance kPa Pipe diameter DN
306 2000 7 0.16 1 40 12 0.28 2 40
406 3000 10 0.23 1 40 17 0.41 3 40
407 4000 13 0.31 2 40 23 0.55 5 40
408 5000 16 0.40 3 40 28 0.68 8 40
508 6000 20 0.50 3 40 35 0.85 9 40
607 7000 22 0.55 3 40 39 0.95 8 40
608 8000 27 0.65 4 40 46 1.1 11 40
511 9000 32 0.80 9 40 54 1.3 23 40
610 10000 35 0.85 7 40 60 1.5 22 40
611 12000 41 1.00 11 40 70 1.7 29 40
712 15000 53 1.30 15 40 90 2.2 40 40
812 18000 63 1.50 16 40 107 2.6 46 40
813 20000 70 1.70 21 40 119 2.9 59 40
915 25000 92 2.20 22 50 154 3.7 59 50
1015 30000 108 2.60 24 40 172 4.22 15 40
1313 35000 122 3.00 20 40 206 5.1 55 40
1315 40000 142 3.40 27 40 228 5.6 19 40
1515 45000 164 4.00 30 40 260 6.2 20 40
1417 50000 180 4.40 43 40 288 7 28 40
1520 60000 212 5.20 11 40 360 8.8 32 40
1720 70000 244 6.00 9 40 416 10.2 24 50
1722 80000 276 6.80 12 40 472 11.6 32 50
1626 90000 292 7.20 3 50 504 12.4 8 50
1826 100000 324 7.84 3 50 568 14 9 50
1852 200000 648 15.68 3 50 1136 28 9 50
3652 400000 1296 31.36 3 50 2272 56 9 50

Unit model EKDM Rated air flow m3/h 2 row
Return air conditions Fresh air conditions
Total cooling capacity kW Water flow l/s Water resistance kPa Pipe diameter DN Total cooling capacity kW Water flow l/s Water resistance kPa Pipe diameter DN
306 2000 11 0.27 1 65 19 0.46 2 65
406 3000 16 0.4 1 65 29 0.7 2 65
407 4000 22 0.53 1 65 38 0.9 4 65
408 5000 27 0.67 2 65 47 1.17 6 65
508 6000 34 0.82 2 65 59 1.4 6 65
607 7000 37 0.9 2 65 65 1.6 6 65
608 8000 45 1.1 3 65 76 1.83 8 65
511 9000 53 1.3 7 65 90 2.2 18 65
610 10000 58 1.4 5 65 99 2.4 15 65
611 12000 69 1.67 8 65 116 2.8 21 65
712 15000 89 2.2 11 65 150 3.6 28 65
812 18000 105 2.5 12 65 178 4.3 33 65
813 20000 117 2.8 15 65 199 5 46 65
915 25000 153 3.7 17 50 256 6.2 43 80
1015 30000 180 4.4 18 65 300 7.4 48 65
1313 35000 204 5 15 65 344 8.4 39 65
1315 40000 238 5.8 21 65 402 10 59 65
1515 45000 272 6.6 22 65 456 11 59 65
1417 50000 302 7.4 32 65 484 12 20 65
1520 60000 352 8.8 9 65 596 14.8 24 65
1720 70000 408 10 7 50 688 16.8 17 80
1722 80000 468 11.6 9 50 784 19.2 23 80
1626 90000 532 13.2 14 50 888 21.2 33 80
1826 100000 592 14.4 14 50 1000 24.8 38 80
1852 200000 1184 28.8 14 50 2000 49.6 38 80
3652 400000 2368 57.6 14 50 4000 99.2 38 80

Note:

■ Temperature of heated inlet water: 60°C; temperature drop 10°C.

■ Fresh air conditions for heating operation: inlet air temperature 0°C; return air temperature 21°C.

■ Coils are copper pipes with aluminum fins (12 fins/inch). EK can provide coils with 8~14 fins/inch.

Air filter

Model
EKDM
Rated air flow m3/h Filter specifications (Qty.)
306 2000 16" x 16" (1) 16" x 20" (1) - -
406 3000 24" x 16" (1) 24" x 20" (1) - -
407 4000 24" x 20" (2) - - -
408 5000 24" x 24" (2) - - -
508 6000 16" x 24" (2) 15" x 24" (2) - -
607 9000 16" x 20" (2) 20" x 20" (2) - -
608 7000 16" x 24" (2) 20" x 24" (2) - -
511 8000 16" x 24" (2) 16" x 20" (1) 15" x 24" (2) 15" x 20" (1)
610 10000 16" x 20" (3) 20" x 20" (3) - -
611 12000 16" x 24" (2) 16" x 20" (1) 20" x 24" (2) 20" x 20" (1)
712 15000 20" x 24" (6) - - -
812 18000 24" x 24" (6) - -

 

Model
EKDM
Rated air flow m3/h Filter specifications (Qty.)
813 20000 24"x20"(8) - - -
915 25000 20" x 20" (2) 20" x 24" (6) 16" x 20" (1) 16" x 24" (3)
1015 30000 20" x 20" (3) 20" x 24" (9) - -
1313 35000 20" x 20" (16) - - -
1315 40000 20" x 20" (4) 20" x 24" (12) - -
1515 50000 24" x 24" (9) 24" x 20" (3) 20" x 24" (3) 20" x 20" (1)
1417 45000 20" x 20" (12) 20" x 24" (3) 24" x 20" (4) 24" x 24" (1)
1520 60000 24" x 24" (3) 20" x 24" (1) 20" x 20" (5) 24" x 20" (15)
1720 70000 20" x 24" (4) 24" x 24" (1) 24" x 20" (5) 20" x 20" (20)
1722 80000 20" x 24" (16) 20" x 20" (8) 24" x 24" (4) 24" x 20" (2)
1626 90000 20" X 24" (25) 20" x 20" (10) - -
1826 100000 20" x 24" (10) 20" x 20" (4) 24" x 24" (15) 24" x 20" (6)

Note:

■ Primary efficiency filter: folding plate; 2 inch thick; nonwoven fabric filtering screen; G3 filtering efficiency (80-90% Arrestance).
■ Medium efficiency filter: bag type; non-woven fabric filtering screen; F5 filtering efficiency (40-60% Dust-spot).
■ Medium High/sub-high efficiency filter: super-thin fiberglass filtering screen; F7~F9 filtering efficiency (80-95% Dust-spot).
■ High efficiency filter: if you need to installed sub-high or high efficiency filters for your knockdown air conditioning units, please contact
EK directly.
■ The resistance of the filter is somewhere between the initial resistance and the final resistance. Initial resistance refers to the resistance of a non-contaminated filter. Final resistance refers to the air resistance of a filter which is contaminated and needs to be cleaned or discarded. Final resistance varies depending on the cleanliness the environment and air in which the air conditioner operates.
■ Besides standard configuration, EK also provides differential pressure gauges and switches for filters. The differential pressure switch controls the differential pressure alarm of the filter.
■ Plate-type filters and bag-type filters have the same sectional area but different thicknesses. Plate-type filters are 2-inch thick; while the frames of bag-type filters are 1-inch thick, with a bag of 15-inch long.

Description:

EK Air handling unit (AHU) air flow range is from 1,000m3/h to 400,000m3/h. Available functional sections include fresh/return air mixing section, cooling coil section, heating coil section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc..

Equipped with double inlet forward/backward pitched centrifugal fans of international name brands and impellers and belt pulleys with motion/rest strictly rectified, the unit works more stably, quietly and efficiently.

The coil features a new type of specially processed antirust fins which can greatly reduce air resistance and motor power consumption. Multiple circuit designs are available for different working conditions to reduce water resistance and improve heat-exchange efficiency.

The water trap of the coil has two valves for water and air discharge, with a test pressure of 3.3MPa and maximum working pressure of 1.7MPa. A Pitched design for the heat insulated condensed water collector ensures smooth discharge of condensed water, leaving the circuit dry all the time.

Each functional section has a specially-designed airtight access door sealed by quality sealing strips. This makes it very convenient to service internal components of the unit while maintaining airtightness of the system.

Robust Structure

The surface of the unit is made of quality color steel, 0.5mm thickness , 1mm is optional ,which can resist corrosion, scratch and ultraviolet radiation.

Internal panels are made of steel plates galvanized with aluminum and zinc, 0.5mm thickness , 1mm is optional , with an assured service life of more than15 years. All panels feature end-to-end joints and smooth surfaces, without any bur or corroded point.

The unit panel has two thicknesses, namely 30mm and 50mm.Inside the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat insulating material. The heat conductivity factor is less than 0.02W/m°C.

Each functional section of the unit is equipped with a steel trough base, thus ensuring it is well supported, easy to transport and assemble. The overall robustness of the unit meets the standard of CEN2.

The unit features a special clamp structure, facilitating disassembly and maintenance as well as ensuring low air leakage. When the internal negative pressure is 1000Pa, the air leakage is below 1% (level B air leakage of European standard EN1886).

Return/Fresh Air AHU

High Air Flow Heat Recovery Air Handling Units

Mixing Air AHU.

High Air Flow Heat Recovery Air Handling Units

Reheating and Humidifying AHU

High Air Flow Heat Recovery Air Handling Units

Clean Room AHU

High Air Flow Heat Recovery Air Handling Units

Clean Room AHU with Return Air Fan

High Air Flow Heat Recovery Air Handling Units

Vertical Air Handling Unit/Heat Recovery AHU

High Air Flow Heat Recovery Air Handling Units

Applications:

Office, Hotel , Hospital ,Supermarket ,Airport , Factory ,Villa .

Competitive Advantage:

Effective Thermal Bridge

• The unit panels are coated with strong and heat-insulating UPVC plastics, thus avoiding direct contact between heat-conductive parts. With a heat-insulation grade of T1 (European standard),thermal bridge and cooling capacity loss are completely eliminated.